Sign In

An official website of the United States government

U.S. Department of Health & Human Services

Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Biosafety Terms

S3: Science Safety Security



Term Definition

Aerosol

Describes microscopic droplets that may contain infectious agents or toxins, similar to the droplets produced by a sneeze or a cough. Some laboratory procedures including sonication, centrifugation, vortexing, flow cytometry, fluorescence-activated cell sorting (FACS) and homogenization can produce aerosols. These procedures should only be performed within a primary containment device.

Antiseptic

An agent that kills or inhibits growth of microbes but is safe to use on human tissue (for example, iodine on a cut in the skin).

Biosafety Cabinets

A type of safety equipment used in biological laboratories that provides protection to the worker and/or materials through directed air flow or a fully sealed workspace.

Biorisk Assessment

A process used to identify acceptable and unacceptable risks and their potential consequences, including biosafety risks (risks of accidental infection) and laboratory biosecurity risks (risks of unauthorized access, loss, theft, misuse, diversion or intentional release). (WHO)

Decontamination

Disinfection or sterilization of articles contaminated with toxins or agents to make the articles safe for use or disposal.

Directional Air Flow

The flow of air from a positively pressurized space to a negatively pressurized space.

Disinfectant

A chemical agent that eliminates a defined scope of pathogenic organisms, but not necessarily all microbial forms (e.g., bacterial endospores).

Disinfection

The selective elimination of certain undesirable microorganisms to prevent their transmission to a susceptible host.

Doffed/Doffing

Describes the act of taking something off (e.g., doffing your gloves).

Donned/Donning

Describes the act of putting something on (e.g., donning a lab coat).

Efficacy

The ability to produce an effect. For example, a disinfectant must be efficacious against a particular infectious agent or toxin in order to be used against that agent or toxin.

HEPA Filters/HEPA Filtration

High Efficiency Particulate Air (HEPA) filters are used to efficiently remove microscopic particles, (including biohazards), from the air stream. HEPA filters are used in biosafety cabinets and in laboratory airflow design.

HVAC System

The term used to describe the heating, ventilation, and air-conditioning systems of a building. The HVAC system includes the building supply and exhaust fans, the duct work, dampers, and the supply diffusor vents and exhaust vents in laboratories. Using fan speed and dampers, individual laboratories can create have the desired negative air flow into the lab from the common corridor (hallway outside of the lab). This negative air flow adds another layer of biocontainment.

Laminar Air Flow

The term describes unidirectional air, moving at a fixed velocity along parallel lines. The turbulence-free air forms a protective “curtain”. This moving “curtain” of air can be used as a barrier, preventing microscopic particles (including biohazards) from crossing the laminar flow air stream. Such particles will be caught in the air stream and directed to a HEPA filter for filtration to remove the particles from the air stream.

Negative Air Flow/Negative Pressurization

Negative air flow describes the process of exhausting more air from a space than is supplied. Negative pressurization is maintaining the barometric pressure of a room or space at a pressure lower than its surrounding environment, which forces air to flow into the space from openings, such as under/around the door. This practice of maintaining negative air flow adds another layer of biocontainment (in addition to work done within primary containment devices). With air constantly being drawn into a laboratory, it is extremely difficult for a microscopic particle (including biohazards) to escape the room. Negative air flow also ensures that when the laboratory door is opened, air will flow into the laboratory instead of out of it.

Occupational Exposure

Any exposure to an infectious agent or toxin which occurs when a person is not a using appropriate personal protective equipment, during an equipment failure, or in an accident such as an animal bite or needle stick. This includes exposure of the skin, eye, or mucous membrane, needle sticks, inhalation, and contact with blood or other potential infectious materials that may result during the performance of a person’s duties.

Personal Protective Equipment (PPE)

Specialized clothing or equipment worn by a worker to provide protection against infectious agents or toxins.

Positive Air Flow/Positive Pressurization

The term describes supplying more air to a space than is exhausted. This forces air from a positively pressurized space to a negatively pressurized space. This can add another level of biocontainment by creating positively-pressurized corridors (hallways) that will provide directional airflow into the negatively-pressurized labs. This ensures that air is always flowing into labs such that when the laboratory door is open, air will flow into the laboratory instead of out.

Primary Containment Device

Specialized items designed to capture or contain infectious agents and toxins biohazards. Biosafety cabinets are one example of a primary containment device. (DSAT)

Risk Assessment

The process of evaluating the risk(s) arising from a hazard(s), taking into account the adequacy of any existing controls, and deciding whether or not the risk(s) is acceptable. (CWA)

Sterile

Free from living microorganisms.

Sterilization

A carefully monitored process that will assure that the probability of an item being contaminated by a microbe to be equal to or less than one in a million (10–6).

Sterility Assurance Level (SAL)

The probability of a viable microorganism being present on a product unit after sterilization. SAL is normally expressed as 10-x. SAL of 10-6 is most often used for sterile devices and drugs.

Standard Operating Procedure (SOP)

Describes a “cook book” style of performing laboratory procedures. Each SOP is documented and laboratory workers are trained so that every laboratory worker performs every task the same, as designated by the SOP.​